Thermocon
Non-Contact Portable Infrared Thermo-Hunters
PT-3L, PT3LD, PT3LF
Temperature Range
20˚C ~ +400˚C
•
Measurement Ares Ø 100/1000mm
•Back-Light Indicator
VF Series
•Temperature Range : 250 ~ 800˚C
1100~2100˚C
•Accuracy : ± 5˚C ± 1 digit of rdg.
BA-BS-BF Built in Series
• Temperature Range
: 600~1200˚C 1000~2000˚C
Built in 2 Series : BA30TA/BA06TA/BA30TV/BA06TV –
Temp 0~500˚C
•Analog Output, Laser Marker, Digital Display
X-400 (Standard Type)
•Temperature Range : 0 ~ 400˚C
•Response : 0.5sec.
•Emissivity Ratio Adjustment : 0.10~1.00(0.01/1 Step)
•Repeatability : ± 1%± 1 digit
•‘MAX’ Function to indicate the maximum temperature during your measurement
•Backlight Function to enable you to read the display even in the dark
Thermocouples, RTDs & Thermowells
Straight type Thermocouples
With Ceramic Outer Sheathing
Temperature rating
• 50˚C up to + 1600˚C
• 0˚C up to + 1200˚C
With Metal Outer Sheathing
• 0˚C up to + 1350˚C
Various Application :
• Furnaces
• Power plants
• Chemical reactors
• Kilns, Incinerator
• Ceramic Industries
• Glass Industries
Angle Type Thermocouples
Temperature rating
• -2000˚C up to + 1200˚C (TC)
• -200˚C up to + 650˚C (RTD)
Temperature
Measurement in Salt
Baths & Metal Melts
Thermocouples & RTDs With
Thermowell & Interchangeable Inset
Temperature rating
• • -200˚C up to + 1200˚C (TC)
• • -200˚C up to + 650˚C (RTD)
In Low & high pressure application, e.g.
• Gaseous & Liquid media
• Pipes & Containment
• Hazardous areas
• Chemical Plants
Insets for
Thermocouples & RTDs Temperature rating
• -200˚C up to + 1200˚C (TC)
• -200˚C up to + 650˚C (RTD)
Used as Interchangeable Insect & Exchangeable in Operation.
Q-185 (Coaxial Laser Marker)
•Temperature Range
:-18 ~ +870˚C
• Rapid Response 0.35Sec.
• Repeatability : ± 0.5% of reading
• Emissivity Adjustment 0.10 ~ 1.00 (0.01/step)
• Analog/Digital Output. 1mv/˚C/digital RS. 232C
5140 (General Purpose Type)
•Measuring Temperature Range
: -50 ~ 500 ˚C (5140S-RS)
•Data Collection (max. 1,000 points)
•Multi-mode Function
•Built-in Red Spot Marker (5140S-RS)
• Analogue Output : (1mv/˚C, ˚F)
•Hi/Low Alarm Output
PT-3S (Pen Type)•Display Range : -30 ~ 230˚C
•Minimum Field of View : Ø 2.5mm
•Repeatability : ± 1˚C
•Response : 0.8sec.
•Analogue Output : (1mv/˚C, ˚F)
Ordering Information :
1Model
2Temperature Range
3Application
4Quantity
Mineral Insulated Thermocouples
• -200˚C up to + 1300˚ C
Mineral Insulated RTDs
• -250˚C up to + 850˚C
Compact and Flexible
Thermometers for use in
•Gaseous & Liquid media
•Pharmaceutical Industries
•Chemical Industries
Plug-in Bayonet
Compression fitting style
Thermocouples & RTDs
Temperature rating
• -200˚C up to + 600˚C
Temp. Measurement e.g. in
• Plastic Industries for Injection Moldings, Blow Moldings, Excluders
• Combustion Engines
• Bearings
RTDs for Air-Conditioning, Ventilating & Heating
Temperature rating
• -200˚C up to ± 400˚C (TC)
Temp. (difference) Measurement e.g. in
• Heating Circuits
• Air Ducts
• Air Conditioned Buildings
• Heat Transfer Systems
General Purpose Thermocouples & RTDs
Temperature rating
• 0˚C up to + 750˚C (TC)
• -50˚C up to + 600˚C (RTD)
Temp. Measurement e.g. in
• Chemical Plants
• Process House, Ovens
• Furnaces, Exhaust
• Service Installation
Different Type of Portable Thermocouples & RTDs
• 0˚C up to + 1000˚C (TC)
• -50˚C up to + 650˚C (RTD)
For Instantaneous Temp. Measurement in
• Furnaces, Ovens, Salt Bath & Incinerator, Process Houses, Paper Mills, Exhaust
Various Accessories
Thermocouples Accessories
Thermowell Drilled From solid Rod
Thermocouples Accessories
FIXED/ADJUSTABLE MALE FITTING :-
Material : M.S., Brass, Stainless Steel.
Size : 1/4", 3/8”, 1/2”, 3/4 ” , 1” B.S.P.,
NPT and mm size also available.
Adjustable Compression Fitting :-
Material : M.S., Brass, Stainless Steel.
Size : 1/4", 3/8”, 1/2”, 3/4 ” , 1” B.S.P.,
NPT and mm size also available.
Quick Disconnect Thermocouple Assembly
Provided with Male & Female-3 Pin Plug-Connector.
Connectors
Thermocouple Types
Type | ANSI Symbol | Temperature Range |
Iron Constantan | J | 0~750˚C |
Chromel Alumel | K | 0~1200˚C |
Copper Constantan | T | -90~400˚C |
Platinum-Platinum | ||
Rhodium 13% | R | 0~1600˚C |
Platinum-Platinum | ||
Rhodium 10% | S | 0~1600˚C |
RTD Consist of Detectors like Pt-100, Pt-500, Pt-200, Pt-1000, Cu-50 etc. can be offered.
Digital Instrumentation
DIGITAL TEMPERATURE INDICATING CONTROLLERS
Type :
1. Thumb wheel Setting
2. Potentiometric Setting
3. Single Relay
4. Two/Three Relay
5. Hi/Low Control Action
6. Proportional Control Action
7. On/Off Control Action
Features :
1. Microprocessor Based
2. Digital Linearisation
3. All Types of Thermocouples / RTDs Inputs
4. Din Cut-Out
5. Inbuilt Cold Junction Compensation
Specification :
1. Sizes : As per Din 43700 & IS 2419 – 1963
2. Inputs : Thermocouples & RTDs
3. Display : 3 ½ Digit
4. General : Power supply
230V AC ± 10%, 50 Hz
110V AC ± 10%, 50 Hz
5. Ambient : 0~60˚C
DIGITAL TEMERATURE INDICATORS :-
Types :
1. Single Channel
2. Multi Channel
3. Indicator with Alarm System
4. Indicator with Big Display
5. Handheld (portable) temperature indicator
Application :
1. Metal Treatments
2. Electro Plating
3. Cold Storage
4. Refrigeration
5. Air-Conditioning
6. Furnaces / Oven / Kilns
7. Plastic Industries
8. Pharmaceutical Industries
9. Textile Process Houses
10. Chemical Process Houses
11. Packaging Industries
ORDERING INFORMATION :
1. Input type : Thermocouple / RTD
2. Temperature Range
3. Model
4. Control Action
5. Application / End Use
6. Quantity
7. Delivery Schedule
Compensating Cables
Between the sensor and the instrument, is the cabling. Thermocouples & RTDs cables are specially calibrated & colour coded according to BS, DIN, ANSI or other international standards. These are used to connect sensors to instrumentation in convenient locations. Insulation varies according to the conditions in which it will have to work. PVC, Polythene, Nylon, Teflon, Fiberglass or Asbestos are substitutes. Screened, Braided and Armoured are also available for special protection.
Ceramic Accessories
Please Furnish the following information, while enquiring/ Ordering for Thermocouples & RTDs :
1. Thermocouple / RTD Type
2. Simplex or Duplex
3. Sheath Length
4. Sheath Diameter
5. Sheath Thickness
6. Sheath Material
7. Measurement in Air, Water, Liquids, Solids,
Granular Materials, Molten Metal etc.
8. Operating Temperature
9. Process Connection
10. Termination
11. Type of Head
12. Compensating Cable Type & Length
DIGITAL TEMERATURE INDICATORS :-
Types :
1. Single Channel
2. Multi Channel
3. Indicator with Alarm System
4. Indicator with Big Display
5. Handheld (portable) temperature indicator
Application :
1. Metal Treatments
2. Electro Plating
3. Cold Storage
4. Refrigeration
5. Air-Conditioning
6. Furnaces / Oven / Kilns
8. Pharmaceutical Industries
9. Textile Process Houses
10. Chemical Process Houses
11. Packaging Industries
Calibraters & Simulators :
1. Hand-Held, Battery-Operated 3 ½ , 4 ½ digit filed calibrators
2. Mains Operated 4 ½ digit table-top mounting calibrator
3. Simulators for Temperature, pH, Conductivity
NEW PRODUCT INFORMATION
PEN TYPE THERMO-HYGROMETER :
Temperature Range : 0~50˚C
Relative Humidity : 2% to 98%
Ultrasonic Distance Finder :
1. Range : 2 feet (0.61m) to 45 feet (13.27m)
2. Measures LENGTH (M1), WIDTH (M2) and HEIGHT (M3) and useful memory function.
3. Calculate AREA (cm2) and VOLUME (cm3) by simple key operation.
Other Products From JAPAN :
1. Non-Contact Portable Technometer
2. Multi Meter
3. Clamp Meter
4. Hand-Held Temperature Meter
5. Stuck On Thermo-clock
6. Sound Level Meter
Two Wire Transmitter :
1. Loop Powered (10 to 42 VDC)
2. RTD, TC, mV, mA, inputs
3. Head mounting (with sensor), Panel Mounting versions available
4. Temperature sensors (RTD, TC) available in aluminum casting & ex-proof housing.
5. 24 VDC Transmitters power supplies 1A, 2A, 5A, 10A